mekay-enerji-sistemleri
MEKAY ENERGY · PRODUCTS & SERVICES

From project equipment to operational data.

Supply of medium-voltage equipment and power transformers; manufacture of low-voltage and SCADA panels; field testing and commissioning. Equipment selection and delivery scope are defined for each project.

01 / MEDIUM VOLTAGE

Switchgear and substation solutions for grid connection

Cubicle functions are selected from the single-line diagram. Our supply portfolio includes modular MV switchgear, concrete and metal substations, cable terminations, protection relays, rectifiers, power cables and auxiliary equipment.

Modular MV switchgear line-up in a production facility
MV switchgear line-up · representative product image

Cubicle functions

Incoming and outgoing feeders, circuit-breaker protection, transformer protection, metering and generator applications are matched to busbar layout, current and short-circuit requirements.

SF₆-free options

For European projects, availability of an SF₆-free model is verified for the requested voltage level and function. The insulation medium and conformity documents are stated in the offer.

Substations and accessories

Concrete or metal enclosures are planned according to internal layout, ventilation, earthing and site installation conditions.

Technical documentation: rated voltage/current, short-circuit withstand, insulation medium, internal-arc classification and test reports are supplied for the selected cubicle model.

Product notes from the earlier site

Metal Clad and Metal Enclosed cubicles

Metal Clad construction uses earthed metal partitions and withdrawable switching devices. Modular Metal Enclosed cubicles have cable/switching, busbar, mechanism and LV control compartments. Select functions against the single-line diagram.

Earlier detail page (Turkish) →

Concrete and steel substations

Concrete units provide compact MV and LV distribution compartments. Steel enclosures may be supplied empty or equipped, depending on site and transport needs; mobile options can be evaluated.

Earlier detail page (Turkish) →

Legacy SF₆-insulated information

Older RMU and Metal Enclosed pages describe SF₆-insulated models. For European SF₆-free requirements, verify the insulation medium and conformity of the currently offered model in its technical file.

Earlier detail page (Turkish) →

Modular cubicle functions

Four sample cubicle views selected by the single-line diagram. Model ratings and interlocks are verified in the offer file.

Line incomer / outgoing · example
Line incomer / outgoing · example
Transformer protection · example
Transformer protection · example
Metering cubicle · example
Metering cubicle · example
Generation feeder · example
Generation feeder · example

Selecting an SF₆-free model

The photograph shows a representative MV cubicle only. Verify the offered model’s insulation medium and gas status in its technical file.

MV cubicle · representative view
MV cubicle · representative view

Steel and concrete substations

Coordinate MV, transformer and LV compartments, ventilation and cable entry with site requirements.

Steel enclosure · example
Steel enclosure · example
Concrete substation · example
Concrete substation · example

MV auxiliary equipment

Cable rating, termination and protection interfaces are specified for the chosen products. Cable and glove images are illustrative.

MV cable
MV cable
Current transformer
Current transformer
Protection relay
Protection relay
DC rectifier
DC rectifier
Cable termination
Cable termination
Insulating platform
Insulating platform
Insulating gloves
Insulating gloves
Surge arrester
Surge arrester
02 / TRANSFORMERS

Power transformers suited to the load profile

We supply hermetically sealed oil-filled, conservator and dry-type transformers according to project conditions. HV/LV ratio and power rating are defined in the enquiry for each application.

Hermetically sealed oil-filled

The sealed-tank design is assessed together with installation space, losses, cooling and maintenance approach.

Conservator type

Options with a conservator system to accommodate changes in oil volume and temperature.

Dry type

Indoor installation, facility safety, ventilation, temperature monitoring and protection requirements are considered.

400 V / 800 V LV output

For PV applications in particular, LV output is selected together with inverter, cable, panel and protection coordination.

Representative oil-filled power transformer
Power transformer · representative product image

Voltage ratio, power rating, frequency, impedance, no-load/load losses, cooling and test scope are confirmed for the proposed model.

Product notes from the earlier site

Sealed oil-filled type

Oil is kept in a sealed tank, with thermal expansion accommodated by corrugated tank walls. Available space and maintenance planning guide selection.

Earlier detail page (Turkish) →

Dry type

Cast-resin windings and air cooling options suit selected indoor uses. Verify ventilation, environmental conditions and fire classification in the model file.

Earlier detail page (Turkish) →

Transformer construction options

Sealed oil-filled, conservator and dry-type designs are assessed against rating, voltage ratio, losses and cooling.

Sealed oil-filled
Sealed oil-filled
Conservator oil-filled
Conservator oil-filled
Dry-type
Dry-type
03 / PANEL MANUFACTURING

LV distribution, PV and industrial panels

Panel scope follows the single-line diagram, short-circuit level, environmental conditions and maintenance access. Mekay Energy covers electrical design, assembly, wiring, labelling and functional checks before delivery.

Front view of an 800 V AC PV distribution panel
800 V AC PV panel · representative application
Internal layout of an LV distribution panel with doors open
LV distribution panel · internal layout and assembly
Distribution and PV panel example

Distribution and PV

Main and sub-distribution, PV AC collection and 400/800 V AC applications.

Industry panel example

Industry

Motor control and power factor correction panels with protection, control and metering functions.

Small-scale PV panel example

Small-scale PV

Compact protection and distribution solutions for detached homes and small commercial rooftops.

Floor-standing, indoor, outdoor and wall-mounted enclosures; ingress protection, sheet-metal construction and compartmentation are determined by project and enclosure series.

Product notes from the earlier site

Distribution panels

Indoor or outdoor conditions, enclosure rating, busbar and breaker layout, fault level and maintenance access guide design. PV AC and 800 V uses require component suitability checks.

Earlier detail page (Turkish) →

Power factor correction panels

Reactive-power demand, step arrangement, metering and harmonic conditions are considered together. Capacitors, reactors and protection follow site measurements and project inputs.

Earlier detail page (Turkish) →

Enclosure production and types

Indoor, outdoor and control enclosures are selected by IP rating and project layout.

Enclosure production area
Enclosure production area
D · indoor floor-standing
D · indoor floor-standing
H · outdoor floor-standing
H · outdoor floor-standing
K · control cabinet
K · control cabinet

800 V AC PV distribution

Confirm 800 V AC suitability of breakers, busbars, metering and protection against inverter and transformer arrangement.

800 V AC · internal assembly
800 V AC · internal assembly
800 V AC · front view
800 V AC · front view

Motor control and power factor

Motor feeders, starting and control, plus reactive-power steps and harmonics, are evaluated separately.

MCC motor control · assembly
MCC motor control · assembly
PFC board · front view
PFC board · front view
PFC board · internal assembly
PFC board · internal assembly

Residential / small-scale PV

Compact protection, metering and connection follow the inverter and grid requirements.

Small PV board · front view
Small PV board · front view
Small PV board · metering and protection
Small PV board · metering and protection
04 / SCADA & AUTOMATION

From field signal to operator screen

RTU/PLC, communications, control panels and SCADA displays are designed together. Measurements, alarms, status and control signals are tested and commissioned at PV plants.

PV substation, RTU and SCADA data-flow architecture
PV field automation · representative data-flow architecture

Panel and architecture

I/O plan, RTU/PLC, industrial network, router, power supply and cyber access boundaries are defined by the project specification.

Integration

Field protocols, telemetry and DSO interfaces are verified against an agreed signal list.

Commissioning

FAT/SAT, point-by-point data checks, alarm and command scenarios, followed by documented handover.

1.5 GW+ of SCADA installation experience refers to the combined installed capacity of the relevant PV plants.

SCADA and RTU panel

I/O lists, DC supply, networks and terminals are aligned with the site architecture.

RTU cabinet · complete view
RTU cabinet · complete view
I/O and network · detail
I/O and network · detail
05 / FIELD TESTING & COMMISSIONING

Verify, document and hand over on site

Measurements and tests for MV switchgear, transformers, LV panels and automation are recorded according to the project acceptance procedure. Technical support is planned around operational needs.

Installation checks

Physical installation, cable connections, labelling, earthing and document conformity.

Functions and protection

Relay settings, interlocks, I/O signals and site operating scenarios.

Documented handover

Measurement results, punch list, corrective actions, acceptance and operational handover.

Electrical field testing and commissioning work
Field testing and commissioning · representative application

Field tests and commissioning

Functional and signal checks are documented against the manufacturer files and acceptance procedure.

Transformer site inspection
Transformer site inspection
MV lineup site inspection
MV lineup site inspection
Cabinet and field connections
Cabinet and field connections
Testing and commissioning
Testing and commissioning

Technical support in operation

Remote support and on-site inspection are scoped to the service agreement and site needs.

Support call · illustrative
Support call · illustrative
Computer-based field inspection · illustrative
Computer-based field inspection · illustrative
TECHNICAL PROPOSAL

Let us start with your project data.

Share your single-line diagram, power and voltage levels, site location, delivery scope and target date. We will confirm model-specific equipment and conformity documentation during the proposal stage.

Send a technical enquiry